Blue-White’s FLEX-PRO A4 Peristaltic Pump Emulates the Success of the FLEX-PRO A3
FLEX-PRO A4 Case Study Facts
Plant: Jones Ferry WTP - Chapel Hill, NC Plant Operator: Dusty Martin Objective: Switch out the diaphragm pump to a peristaltic pump to create a smooth, consistent flow rate that is most acceptable for dosing. Challenge: Seeking a peristaltic pump that can run 24/7 at 84 GPH, pumping against a low psi (<15). Current pump: Prominent Diaphragm Current problem with using a diaphragm pump: Creates an inconsistent flow rate due to the inherent nature of the pulsating operation of the diaphragm. Application/Chemical: 2% Potassium Permanganate feeding between 2 1/2 and 4 parts per million. Reason for using Potassium Permanganate: High levels of Oxide Iron and Magnesium in well water. Injecting the Potassium Permanganate prevents yellowing of the water and staining. However, too much of the chemical creates a pinkish tint to the water. Reason for using the PERFECT peristaltic pump: The Jones WTP is attempting to achieve a Level 4 Standard in accordance with the national organization "Partnership to Save Water". They are hoping to become one of seven plants in the country to achieve such a standard. The standard is based partly on the level of turbidity of the water. The yellow water is a natural occurrence from the wells in this part of the country. Moreover, yellow water is reflected on the turbidity readings as dirty water. Eliminating the yellow water results in a cleaner reading, hence a Level 4 is achievable. Maintaining the precise amount in the most consistent manner is critical for clear, clean water. Tested: Periflo, Masterflex, Blue-White FLEX-PRO A4 Results: Both the Periflo and Masterflex pumps' tubes failed after 8 days. However, the Blue-White Flex-Pro A4 has out- performed both Periflo and Masterflex. The Blue-White FLEX-PRO A4 test began June 1st, 2010 and thus far has surpassed all expectations with over 1600 hours of tube life. A final tube life conclusion in this application will be forthcoming in the months ahead. Reason for Success per Plant Manager: The Blue-White A4 contains four rollers (two for guiding and two for compressing) while the Periflo and the Masterflex have three. This special roller assembly on the Flex-Pro A4 and the A3 creates less wear of the tube as inferred by the plant manager. In addition, it should also be noted that the Flex-Pro Norprene tubes are manufactured in accordance to Blue-White’s specifications and therefore unique to Blue-White.
Additional FLEX-PRO A3 Installations at the Jones Ferry Rd WTP:
Update on existing A3 fluoride injection pump usage:
Tube life (Norprene) is lasting 9448 hours, 24/7, pressure <15psi
Update on existing A3 sodium hypo flash mixer consisting of ten A3 pumps:
Tube life (Norprene) is lasting 7000 - 7500 hours, 24/7, pressure <15psi
Update on existing A3 sodium hypo post mixer;
Tube life (Norprene) is lasting 1500 - 1700 hours, 24/7, pressure 80 PSI  
|
 |
| |
 |
|
 |